Struggling with a Ariston Error Code 108: Causes, Fixes and Safe Checks? We can help.
[allstar_fault_code_search]
Ariston error code 108 guide explaining low water pressure, filling needed, pressure checks, possible leaks and engineer advice from Allstar Systems Plumbing & Heating.

Ariston 108 Error: Filling Needed and Safe Next Steps

Ariston 108 means the sealed heating circuit needs attention. The reading has fallen below the level required for normal operation.

As a result, the appliance could stop. This protects key parts and prevents poor performance.

In many cases, the fix is simple. However, if the message returns, do not keep adding more water. A hidden leak or faulty part may need checking.

What does Ariston 108 mean?

The 108 message often means “filling needed”. In plain terms, the gauge reading sits too low.

This does not usually point to a major internal failure. Instead, the pipework, radiators, or filling loop may need attention.

Even so, repeated drops matter. If the same message appears again, the cause needs proper diagnosis.

Why the 108 message appears

Several common issues can lower the reading. Some happen after normal user checks. Others need a qualified repair.

Radiators have recently been bled

Bleeding radiators releases trapped air. Yet, it can also lower the gauge reading.

Afterwards, you may need to top up the sealed circuit. Always follow the manual for your exact model.

A small leak is present

A tiny drip can cause repeat pressure loss. Look around radiator valves, towel rails, exposed pipework, and visible joints.

Also, check below the appliance for signs of moisture.

The filling loop has not worked correctly

The filling loop lets you restore the correct level. If it has not opened fully, the reading may remain low.

However, if it fails to close properly, it may create further pressure problems.

The expansion vessel needs testing

The expansion vessel helps handle changes as water heats up. If it loses charge or fails, the gauge may move more than it should.

This part needs professional testing.

The relief valve has discharged

A relief valve opens when pressure rises too high. If this has happened, water may leave through the outside discharge pipe.

If you see dampness near the copper pipe outside, arrange a repair.

Safe checks before booking a visit

First, check the gauge when the appliance is cold. Many sealed systems sit around 1 to 1.5 bar. However, your manual gives the correct figure.

Next, look for visible leaks around radiators, valves, pipework, and below the casing.

Then, top up only if the manual explains the process clearly. Stop when the gauge reaches the stated range.

After that, follow any reset or mode-button steps shown in your manual.

If the message returns, stop refilling. Repeated top-ups can hide a leak and could cause extra damage.

Can you fix this yourself?

You may clear the message by restoring the correct fill level. This is safe only when you follow the manufacturer’s steps.

However, do not open the casing, adjust sealed parts, or keep topping up again and again.

When should you call an engineer?

Call a Gas Safe registered engineer if the message returns after topping up. Also, get help if the gauge falls again within a short time.

You should also book a visit if you find a leak, notice dampness near the discharge pipe, or see the gauge rise too high when the appliance warms up.

A professional can inspect the filling loop, check for leaks, test the expansion vessel, and confirm safe operation.

How to reduce future 108 messages

Watch the gauge after radiator bleeding. This helps you spot changes early.

Also, act fast if you notice damp patches, dripping valves, or repeated top-ups.

Annual servicing helps too. During a service, an engineer can check safety parts, review readings, and spot early wear.

Final advice

Ariston 108 usually means the sealed circuit needs refilling. It is often a straightforward user check.

However, repeat pressure loss points to another issue. Do not keep adding water without finding the cause.

Because the problem could involve a leak, filling loop, expansion vessel, or relief valve, safe diagnosis is important.

Ariston 108 fault code FAQs

What is Ariston error code 108?

Ariston error code 108 means the boiler has detected very low water pressure in the system.

Yes, leaks can cause pressure to fall quickly. Therefore, they are a common reason for this fault.

Yes, you can try a reset after repressurising the system. However, if the fault returns, you should call an engineer.

Not always. Sometimes the system simply needs topping up. However, repeated pressure loss can point to a leak or failed part.

It can stop the boiler from working properly. Therefore, it should be checked promptly.

A qualified heating engineer should diagnose and repair ongoing pressure loss or faulty boiler components.

Share this post

Trusted Plumber
Allstar Systems

Trusted Local Plumbing & Heating Experts

✓ Gas Safe & OFTEC Registered
✓ Hundreds of Happy Customers
✓ Emergency Callouts Available
✓ Professional & Friendly Engineers

Allstar Systems Ltd
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.